Gaseous Co2
  Liquid Co2
  Solid Co2 (Dry Ice)
  Total Package
     Storage Tanks
     Vaporiser
     Insulation
     Refrigeration Unit
     Safety Valve
     PressureReduction Stn.
     Transfer Pumps
     Cylinder Filling Pumps
     Dry Ice Press
     Cylinder Manifold
     Dry Ice Press
 

 
INSULATION
 

 

Polyol & Isocyanide in ratio of 1 : 1
The PUF is poured in situ to form insulation over the tank after painting the tank with polyurethane paint.
Thickness of insulation is 200mm all over, and checked for density requirement at different parts at random.

PUF

PUF has a closed cell foam structure of extremely low thermal conductivity.
Lowest maintenance costs and longer life of tank
Very low ageing rate ensures stable performance
Structurally strong and its low weight does not add much tare weight to tank

CLADDING MATERIAL

22 gauge thick Aluminium (sheet) bright cladding sheet is provided over the insulation as a protective measure.
The sheets seams are either riveted or screwed by self taping screws.
To prevent water seepage, the joints are closed by silicon sealant and also to prevent atmospheric moisture to get into tank insulated surface.

For any information / Co2 requirements, contact :

SICGIL INDIA LIMITED
VI Floor, Dhun Building, # 84, (Old No. 827), Anna Salai, Chennai-600 002.
Phone : 91 - 044 - 2852 1644 / 2852 1467 / 2852 0657 / 2852 0870
Fax : 91 - 044 - 2852 1249, E-mail : sicgil@vsnl.com, vijay@sicgil.com,
Contact Persons
V.N.Vijay Kumar
Phono No: 044 39850715/728
Ruqshad Dadabhoy
   

_____________________________________________________________________
At : Bangalore, Chennai, Cochin, Coimbatore, Goa, Hyderabad, Indore, Kakinada, Kolkata, Madurai, Mumbai, Surat, Tuticorin, Vadodara, Vizag.

 


 
Sitemap l Disclaimer                                                                                          ©2005 SICGIL INDIA LIMITED. All rights reserved.